期刊文献+

Ruby (Al_2O_3∶Cr^(3+)) Fluorescence Thermometer Using PLD-PMSR Technique

Ruby (Al_2O_3∶Cr^(3+)) Fluorescence Thermometer Using PLD-PMSR Technique
下载PDF
导出
摘要 A kind of fluorescence fiber-optic thermometer is devised based on the solid-state ruby fluorescence material. The characteristics of fluorescence material absorption and emission are analyzed, and the fiber-optic temperature measurement probe in ruby is developed. This system is particularly adaptable to the temperature measurement in the range of 20℃ to 600℃. During the experiment, this method is proved to be useful to temperature measurement with high resolution and precision. A kind of fluorescence fiber-optic thermometer is devised based on the solid-state ruby fluorescence material. The characteristics of fluorescence material absorption and emission are analyzed, and the fiber-optic temperature measurement probe in ruby is developed. This system is particularly adaptable to the temperature measurement in the range of 20 ℃ to 600 ℃. During the experiment, this method is proved to be useful to temperature measurement with high resolution and precision.
出处 《Semiconductor Photonics and Technology》 CAS 2005年第4期259-262,共4页 半导体光子学与技术(英文版)
基金 NationalNaturalScienceFoundationofChina(62672027)
关键词 Fluorescence fiber-optic thermometer Ruby material PLD-PMSR 温度计 传感器 荧光性 光学纤维 Ruby材料
  • 相关文献

参考文献10

  • 1Sholes R R, Small J G. Fluorescent decay thermometer with biological applications[J]. Review of Scentific Instruments,1980, 51(7): 882-884.
  • 2Bosselmann Th, Reule A, Schroder J. Fiber-optic temperature sensor using fluorescent-ce decay time[J]. Proc. SPIE,1984, 514: 151-154.
  • 3Grattan K T V, Selli R K, Palmer A W. Ruby decay-time fluorescence thermometer in a fiber-optic configuration[J].Review of Scientific Instruments, 1988, 59(8): 1 328-1 335.
  • 4Wickersheim K, Sun M. Phosphors and fiber optics remove doubt from difficult temperature measurements[J]. Research & Development, 1985, 27(11): 114-119.
  • 5Zhang Z Y, Grattan K T V, Palmer A W. A novel signal-processing scheme for fluorescence based fiber-optic temperature sensor[J]. Review of Scientific Instruments, 1991 ,62 (7): 1 735-1 742.
  • 6Grattan K T V, Palmer A W, ZhangZ Y. Development of a high-temperature fiber-optic thermometer probe using fluorescent decay[J]. Review of Scientific Instruments, 1991, 62 (5): 1 210-1 213.
  • 7Manufacturer's Data[K]. USA: Fiberguide Industries, 1989.
  • 8Burns G, Nathan M. Quantum efficiency of ruby[J]. J. Appl. Phys., 1963, 34 (3): 703-705.
  • 9Manufacturer's Data[K]. Canada: Johnson Matthey Ltd. , 1989.
  • 10Augousti A T, Grattan K T V, Palmer A W. A laser-pumped temperature sensor using fluorescent delay time of alexandrite[J]. J. Lightwave Technology, 1987, LT-5(6): 759-762.