摘要 基于在稀磷酸介质中,钌(Ⅲ)对高碘酸钾与天青Ⅰ的氧化褪色反应的催化作用,建立了微量钌的催化光度测定法.对此催化反应条件的优化试验及反应的动力学参数的测定,确定了反应介质的磷酸浓度0.48 mol·L-1,测定波长620 nm,反应的温度条件65~100 ℃,为操作方便,方法采用在沸水浴中加热7 min,测得表观活化能(Ea)为17.70 kJ·mol-1,反应速率常数(K)为3.7×10-4s-1,钌(Ⅲ)浓度在0~0.48 mg·L-1范围内,与lg(A0/A)值呈线性关系(相关系数为0.999 3),其检出限为0.040 mg·L-1,对0.24 mg·L-1钌(Ⅲ)进行11次测定,算得RSD为2.0%.此方法应用于三个含不同量钌的模拟试样分析,所得结果与已知值相符. A new catalytic photometric method for determination of ruthenium(Ⅲ) based on the catalytic action of Ru (Ⅲ) on the oxidation-decoloration reaction of azure Ⅰ by KIO4 in a ditute H3PO4 medium is established. Through a study of the optimum condition of the catalytic reaction together with its reaction kinetics, following results were obtained: concentration of H3PO4 of the reaction solution: 0. 48 mol · L^-1 ; wavelength of determination: 620 nm; optimum reaction temperature: 65-100℃;, Heating in a boiling water bath for 7 min was adopted in the method; apparent activity energy (Ea) of the catalytic reaction was found to be 17. 70 kJ · mol^-1 ; reaction rate constant (K) of the catalytic reaction was found to be 3. 7 × 10^-4 s^-1 ; linear relationship between lg (A0/A) and concentration of Ru(Ⅲ) was obtained in the range of 0-0. 48mg · L^-1 (r=0. 999 3) with a detection limit of 0. 040 mg · L^-1 ; test for precision was performed at Ru( Ⅲ ) concentration level of 0. 24 mg · L^-1 and the RSD (n= 11) found was 2. 0%. The proposed method has been applied to the determination of Ru( Ⅲ) in 3 simulated samples, the results obtained were in consistency with the known values.
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2005年第11期845-846,852,共3页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 催化光度法 天青Ⅰ Catalytic photometry Ruthenium(Ⅲ) Azure Ⅰ
  • 相关文献

参考文献4

二级参考文献12

共引文献28

同被引文献79

引证文献11

二级引证文献35

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部