文章报道了宝钢集团上海梅山钢铁股份有限公司2#炼铁高炉净循环冷却水用低磷低锌阻垢缓蚀剂JA-211B的试验开发和应用情况。经现场应用1年,从停炉体风打开水冷设备检查情况表明,JA-211B取得了很好的阻垢、缓蚀效果。
Development and in-situ application of scale-corrosion inhibitor JA-211B with low concentration of phosphate and zinc in 2^# blast furnace clear recirculating cooling water system of Shanghai Meishan Iron and Steel Corporation Ltd. of Bao Steel Group are introduced. One year operation results show that scale-corrosion inhibitor JA-211B has very good scale and corrosion inhibition performance.