期刊文献+

Determination of optimal source-detector separation in measuring chromophores in layered tissue with diffuse reflectance 被引量:3

Determination of optimal source-detector separation in measuring chromophores in layered tissue with diffuse reflectance
原文传递
导出
摘要 Based on analysis of the relation between mean penetration depth and source-detector separation in a threelayer model with the method of Monte-Carlo simulation, an optimal source-detector separation is derived from the mean penetration depth referring to monitoring the change of chromophores concentration of the sandwiched layer. In order to verify the separation, we perform Monte-Carlo simulations with varied absorption coefficient of the sandwiched layer. All these diffuse reflectances are used to construct a calibration model with the method of partial least square (PLS). High correlation coefficients and low root mean square error of prediction (RMSEP) at the optimal separation have confirmed correctness of the selection. This technique is expected to show light on noninvasive diagnosis of near-infrared spectroscopy. Based on analysis of the relation between mean penetration depth and source-detector separation in a threelayer model with the method of Monte-Carlo simulation, an optimal source-detector separation is derived from the mean penetration depth referring to monitoring the change of chromophores concentration of the sandwiched layer. In order to verify the separation, we perform Monte-Carlo simulations with varied absorption coefficient of the sandwiched layer. All these diffuse reflectances are used to construct a calibration model with the method of partial least square (PLS). High correlation coefficients and low root mean square error of prediction (RMSEP) at the optimal separation have confirmed correctness of the selection. This technique is expected to show light on noninvasive diagnosis of near-infrared spectroscopy.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第11期659-661,共3页 中国光学快报(英文版)
基金 This work was supported by the Tenth Five Years Plan of China (No. 2004BA706B12) the Natural Science Key Foundation of Tianjin (No. 023800411).
关键词 Calibration Detectors Diagnosis Diffusers (optical) Infrared spectroscopy Monte Carlo methods REFLECTION Sandwich structures SEPARATION Calibration Detectors Diagnosis Diffusers (optical) Infrared spectroscopy Monte Carlo methods Reflection Sandwich structures Separation
  • 相关文献

同被引文献17

引证文献3

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部