期刊文献+

1.5 Harmonic Imaging Sonography with microbubble contrast agent improves characterization of hepatocellular carcinoma 被引量:1

1.5 Harmonic Imaging Sonography with microbubble contrast agent improves characterization of hepatocellular carcinoma
下载PDF
导出
摘要 AIM: To investigate the usefulness of 1.5 Harmonic Imaging Sonography with the use of the contrast agent Levovist for the diagnosis of hepatocellular carcinoma (HCC) and for the evaluation of therapeutic response.METHODS: Phantom experiments were performed to compare the contrast effects of 2nd harmonic imaging and 1.5 Harmonic Imaging Sonography. 1.5 Harmonic Imaging Sonography was employed to examine 36 patients with HCC (42 nodules) before and after the treatment and to compare against the findings obtained using other diagnostic imaging modalities. RESULTS: In 1.5 Harmonic Imaging Sonography, the tumor vessels of HCCs were clearly identified during the early phase, and late-phase images clearly demonstrated the differences in contrast enhancement between the tumor and surrounding hepatic parenchyma. Blood flow within the tumor was detected in 36 nodules (85.7%)during the early phase and in all 42 nodules (100%) during the late phase using 1.5 Harmonic Imaging Sonography,in 38 nodules (90.5%) using contrast-enhanced CT, in 34nodules (81.0%) using digital subtraction angiography (DSA), and in 42 nodules (100%) using US CO2angiography.Following transcatheter arterial embolization, 1.5Harmonic Imaging Sonography detected blood flow and contrast enhancement within the tumors that were judged to contain viable tissue in 20 of 42 nodules (47.6%).However, 6 of these 20 cases were not judged in contrastenhanced CT. 1.5 Harmonic Imaging Sonography was compared with the US CO2 angiography findings as the gold standard, and the sensitivity and specificity of these images for discerning viable and nonviable HCC after transcatheter arterial embolization were 100% and 100%,respectively.CONCLUSION: 1.5 Harmonic Imaging Sonography permits the vascular structures of HCCs to be identified and blood flow within the tumor to be clearly demonstrated.Furthermore, 1.5 Harmonic Imaging Sonography is potentially useful for evaluating the therapeutic effects of transcatheter arterial embolization on HCC. AIM: TO investigate the usefulness of 1.5 Harmonic Imaging Sonography with the use of the contrast agent Levovist for the diagnosis of hepatocellular carcinoma (HCC) and for the evaluation of therapeutic response. METHODS: Phantom experiments were performed to compare the contrast effects of 2^rd harmonic imaging and 1.5 Harmonic Imaging Sonography. 1.5 Harmonic Imaging Sonography was employed to examine 36 patients with HCC (42 nodules) before and after the treatment and to compare against the findings obtained using other diagnostic imaging modaUties. RESULTS: In 1.5 Harmonic Imaging Sonography, the tumor vessels of HCCs were clearly identified during the early phase, and late-phase images clearly demonstrated the differences in contrast enhancement between the tumor and surrounding hepatic parenchyma. Blood flow within the tumor was detected in 36 nodules (85.7%) during the early phase and in all 42 nodules (100%) during the late phase using 1.5 Harmonic Imaging Sonography, in 38 nodules (90.5%) using contrast-enhanced CT, in 34 nodules (81.0%) using digital subtraction angiography (DSA), and in 42 nodules (100%) using US CO2angiography. Following transcatheter arterial embolization, 1.5 Harmonic Imaging Sonography detected blood flow and contrast enhancement within the tumors that were judged to contain viable tissue in 20 of 42 nodules (47.6%). However, 6 of these 20 cases were not judged in contrastenhanced CT. 1.5 Harmonic Imaging Sonography was compared with the US CO2 angiography findings as the gold standard, and the sensitivity and specificity of these images for discerning viable and nonviable HCC after transcatheter arterial embolization were 100% and 100%,respectively. CONCLUSION: 1.5 Harmonic Imaging Sonography permits the vascular structures of HCCs to be identified and blood flow within the tumor to be clearly demonstrated. Furthermore, 1.5 Harmonic Imaging Sonography is potentially useful for evaluating the therapeutic effects of transcatheter arterial embolization on HCC. 2005 The WJG Press and Elsevier Inc. All rights reserved
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第36期5607-5613,共7页 世界胃肠病学杂志(英文版)
关键词 1.5谐波成像 超声检查 肝细胞癌 临床表现 1.5 Harmonic imaging sonography Hepatocellular carcinoma Microbubble
  • 相关文献

参考文献22

  • 1Choi BI, Kim TK, Han JK, Kim AY, Seong CK, Park SJ. Vascularity of hepatoceller carcinoma :assessment with contrastenhanced second-harmonic versus conventional power Doppler US. Radiology 2000; 214:381-386.
  • 2Hosten N, Puls R,Lemke AJ, Steger W, Zendel W, Zwicker C,Felix R. Contrastenhanced power Doppler sonography: Improved detection of characteristic flow patterns in focal liver lesions. J Clin Ultrasound 1999; 27:107-115.
  • 3Ding H, Kudo M, Onda H, Suetomi Y, Minami Y, Chung H,Kawasaki T, Maekawa K. Evaluation of Posttreatment Response of hepatocellular carcinoma with contrast-enhanced coded phase-inversion harmonic US: comparison with dynamic CT. Radiology 2001; 221:721-730.
  • 4Heckemann RA, Cosgrove DO, Blomley MJ, Eckersley RJ,Harvey CJ, Mine Y. Liver lesions: intermittent second-harmonic gray-scale US can increase conspicuity with microbubble contrast material - early experience. Radiology 2000; 216:592-596.
  • 5Harvey CJ, Blomley MJ, Eckersley RJ, Heckemann RA, Butler-Barnes J, Cosgrove DO. Pulse-inversion mode imaging of liver specific microbubbles:improved detection of subcentimetre metastases. The Lancet 2000; 355:807-808.
  • 6Blomley MJ, Albrecht T, Cosgrove DO, Patel N, Jayaram V,Butler-Barnes J, Eckersley RJ, Bauer A, Schlief R. Improved imaging of liver metastases with stimulated acoustic emission in the late phase of enhancement with the US contrast agent SH U 508A: early experience. Radiology 1999; 210:409-416.
  • 7Burns PN, Wilson SR, Muradali D, Microbubble destruction is the origin of Harmonic signals from FS 069. Radiology 1996;201:158-159.
  • 8Calliada F, Campani R, Bottinelli O, Bozzini A, Sommaruga MG. Ultrasound contrast agents basic principals. Eur J Radiol 1998; 27:157-160.
  • 9Wilson SR, Burns PN, Muradali D, Wilson JA, Lai X. Harmonic hepatic US with microbubble contrast agents:initial experience showing improved characterization of hemangioma,hepatocellular carcinoma,and metastasis. Radiology 2000; 215:153-161.
  • 10Blomley MJ, Albrecht T, Cosgrove DO, Eckersley RJ, Butler Barnes J, Jayaram V, Patel N, Heckemann RA, Bauer A, Schlief R. Stimulated acoustic emission to image a late liver and spleen-specific phase of Levovist in normal volunteers and patients with and without liver disease. Ultrasound Med Biol 1999; 25: 1341-1352.

同被引文献11

引证文献1

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部