摘要
针对民用航空器喷漆作业时,喷枪喷射流区域的爆炸危险性区域划分问题,进行了一系列的试验,并对试验过程中未发生爆炸的原因进行了分析,为喷漆维修作业的爆炸危险区域划分提出了建议。
Based on the division of explosion hazard areas in the spraying of the civil aerostat,a series of experiments have been done. The reasons that no explosion occurred during the experiment have been analyzed. Suggestions on the division of explosion hazard area in spraying maintenance have been given.
出处
《消防科学与技术》
CAS
2005年第6期691-694,共4页
Fire Science and Technology
关键词
爆炸
爆炸危险区域
爆炸极限
工艺防火
explosion
explosion hazard are
explosion limit
technological fire protection