摘要 采用一种预装的流动注射功能块流路,以4-氨基安替比林为显色剂,流动注射-分光光度法测定了水样中的酚.提出流动注射固定化和标准化流路硬件,依靠软件程序选择流路参数的优化方法,并采用一种在线膜过滤装置过滤混浊样品,直接进行测定.这种过滤装置不堵塞,可连续运行30 h以上.所拟定的方法酚的质量浓度在0.1~8.0 mg/L与吸收值呈线性关系,相关系数为0.999,方法的检出限为0.05 mg/L (3σ,n=11).样品平行测定的相对标准偏差(RSD,n=5)<2.1%,回收率为97.0%~104.3%,采样频率为60/h以上.用此法测定油田水及管道废水中酚的结果与常用蒸馏法结果相符. Based on the chromagenic reaction of 4-amino-antipyrine with phenol, a procedure for direct determination of phenol in waste water has been developed. Integrated manifold module connected with on-line membrane filter system was used in order to improve the robustness and the stability of the flow injection system. The linear range of the method is 0.1-8.0 mg/L with detection limit of 0.05 mg/L for phenol (3σ, n = 11 ). The sample throughout is higher than 60/h. The recovery of standard addition is 97.0% - 104.3% with precision of less than 2.1% RSD ( n = 5 ). The suggested system has been applied to the determination of phenol in oil field water and sewage water. The results are in agreement with those obtained by common distillation method.
出处 《岩矿测试》 CAS CSCD 2005年第4期245-248,共4页 Rock and Mineral Analysis
基金 国家科技部"十五"攻关项目(02031005)
关键词 流动注射 预装功能流路 在线膜过滤 phenol flow injection integrated manifold module membrane-filter system
  • 相关文献

参考文献9

  • 1ISO 6439-1990, Water Qulity-Determination of Phenol Index-4-Aminoantipyrine Spectrometric Methods after Distillation[S].
  • 2Ong C P, Lee H K, Li S F Y. Optimization of Mobile Phase Composition for High-performance Liquid Chromatographic Analysis of Eleven Priority Substituted Phenols[J]. J Chromatogy,1989,464(2):405-410.
  • 3Puig D, Barceló D. Determination of Phenolic Compounds in Water and Waste Water[J].Trends in Analytical Chemistry,1996,15(8):362-375.
  • 4ATMS D1783-2001,Standard Test Methods for Phenolic Compounds in Water[S].
  • 5GB7490-1987.水质挥发酚的测定蒸馏后4-氨基安替比林分光光度法[S].[S].,..
  • 6Friestad H O, Ott D E, Gunther F A. Automated Colorimetric Microdetermination of Phenols by Oxidative Coupling with 3-Methyl-2-Benzothiazolinone Hydrazone[J].Anal Chem, 1969,41(13):1750-1754.
  • 7Morris E,Gales Jun. An Evaluation of the 3-Methyl-2-Benzothiazolinone Hydrazone Method for the Determination of Phenols in Water and Waste Waters[J]. The Analyst,1975,100(1197):841-847.
  • 8Frenzel W, Mrlen J O F. Spectrophotmetric Determination of Phenolic Compounds by Flow-Injection Analysis[J]. Anal Chim Acta,1992,261(1-2):253-259.
  • 9李铁虎,林守麟,郭伟.一种改进的测定水中亚硝酸盐的FIA停流-分光光度法研究[J].分析科学学报,2004,20(5):471-473. 被引量:5

二级参考文献3

共引文献5

同被引文献9

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部