期刊文献+

Recurrent atrial tachycardia and atrial fribrillation after circumferential pulmonary vein ablation:What’s the difference? 被引量:13

Recurrent atrial tachycardia and atrial fribrillation after circumferential pulmonary vein ablation:What’s the difference?
原文传递
导出
摘要 Background Recurrent atrial tachyarrhythmia (ATa) after circumferential pulmonary vein ablation (CPVA) includes atrial tachycardia (AT) and atrial fribrillation (AF). However, whether there are some differences in clinical course and mechanisms between the recurrent AT and the recurrent AF remained unclear. This study was conducted to investigate the incidence, mechanism, clinical course of the recurrent AT and AF in patients under CPVA.Methods One hundred and thirty consecutive patients (M/F = 95/35 ) with highly symptomatic ano multiple antiarrhythmic drugs (AADs) refractory paroxysmal ( n = 91 ) or persistent ( n = 39 ) AF were included. The ablation protocol consisted solely of two continuous circular lesions around the ipsilateral pulmonary veins (PV) guided by CARTO system. The endpoint of CPVA is PV isolation. For patients with recurrent ATa within 2 months after the initial procedure, cardioversion with direct current was attempted if the ATa lasted for more than 24 hours. A repeat ablation procedure was performed only for patients with AADs refractory recurrent ATa and at least followed up for 2 months after the initial procedure.Results Within 2 months after the initial procedure, 52 patients (40. 0% ) had experienced episodes of symptomatic recurrent ATa. Among them, 23 patients (44.2%) with recurred AT alone (AT group ), 14 patients (26.9%) with recurred AF alone (AF group), and 15 patients (28.8%) with recurred AT and AF (AT plus AF group). The delayed cure rate (65.2%) in AT group was significant higher than that in AF group (21.4%, P〈0.05) and AF plus AT group (26.7%, P 〈0.05). A repeat ablation was performed in 21 patients, including 6 patients with recurrent AT alone, 8 patients with recurrent AF alone, and 7 patients with recurrent AF plus AT. The mean number of PV gaps was 1.2 ± 0. 4 in AT group, which was significantly lower than that in AF group (2.6 ± 0. 7, P 〈 0.05) and AF plus AT group (2.0 ± 0.6, P 〈 0.05). Delayed cure rate and number of PV gaps between AF group and AF plus AT group were comparable (P 〉 0.05 ). Conclusions Present study indicates that recurrent AT and AF after CPVA have the different clinical course and different electrophysiological findings during repeat procedure as follows: (1)After CPVA, spontaneous resolution of recurrent ATa was mainly found in patients with recurrent AT alone (about two thirds patients). (2) The type of recurrent ATa after CPVA is associated with the numberof PV gaps. Background Recurrent atrial tachyarrhythmia (ATa) after circumferential pulmonary vein ablation (CPVA) includes atrial tachycardia (AT) and atrial fribrillation (AF). However, whether there are some differences in clinical course and mechanisms between the recurrent AT and the recurrent AF remained unclear. This study was conducted to investigate the incidence, mechanism, clinical course of the recurrent AT and AF in patients under CPVA.Methods One hundred and thirty consecutive patients (M/F = 95/35 ) with highly symptomatic ano multiple antiarrhythmic drugs (AADs) refractory paroxysmal ( n = 91 ) or persistent ( n = 39 ) AF were included. The ablation protocol consisted solely of two continuous circular lesions around the ipsilateral pulmonary veins (PV) guided by CARTO system. The endpoint of CPVA is PV isolation. For patients with recurrent ATa within 2 months after the initial procedure, cardioversion with direct current was attempted if the ATa lasted for more than 24 hours. A repeat ablation procedure was performed only for patients with AADs refractory recurrent ATa and at least followed up for 2 months after the initial procedure.Results Within 2 months after the initial procedure, 52 patients (40. 0% ) had experienced episodes of symptomatic recurrent ATa. Among them, 23 patients (44.2%) with recurred AT alone (AT group ), 14 patients (26.9%) with recurred AF alone (AF group), and 15 patients (28.8%) with recurred AT and AF (AT plus AF group). The delayed cure rate (65.2%) in AT group was significant higher than that in AF group (21.4%, P〈0.05) and AF plus AT group (26.7%, P 〈0.05). A repeat ablation was performed in 21 patients, including 6 patients with recurrent AT alone, 8 patients with recurrent AF alone, and 7 patients with recurrent AF plus AT. The mean number of PV gaps was 1.2 ± 0. 4 in AT group, which was significantly lower than that in AF group (2.6 ± 0. 7, P 〈 0.05) and AF plus AT group (2.0 ± 0.6, P 〈 0.05). Delayed cure rate and number of PV gaps between AF group and AF plus AT group were comparable (P 〉 0.05 ). Conclusions Present study indicates that recurrent AT and AF after CPVA have the different clinical course and different electrophysiological findings during repeat procedure as follows: (1)After CPVA, spontaneous resolution of recurrent ATa was mainly found in patients with recurrent AT alone (about two thirds patients). (2) The type of recurrent ATa after CPVA is associated with the numberof PV gaps.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2005年第21期1773-1778,共6页 中华医学杂志(英文版)
基金 This work was funded by grants of China " Tenth Five" ResearchProject ( No.2004BA714B04) and Young Investigator TrainingProgram from Beijing Municipal Science and Technology Commission(No.H013610150113)
关键词 atrial fibrillation catheter ablation pulmonary vein atrial fibrillation catheter ablation pulmonary vein
  • 相关文献

同被引文献44

引证文献13

二级引证文献72

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部