期刊文献+

ProPex根管测量仪测量磨牙牙齿操作长度准确性的临床评价 被引量:7

Clinical evaluation on accuracy of a new apex locator-ProPex in molar working length measurement
下载PDF
导出
摘要 目的:评价分析ProPex根管测量仪测量磨牙牙齿操作长度的准确性。方法:选择116例根管治疗术的患者共130个磨牙383个根管,分为3组。A组:因根管欠充须再治疗者30个牙91个根管;B组:因修复治疗需要去髓术者46个牙130个根管;C组:慢性根尖周炎54个牙162个根管。以Propex测量牙齿操作长度。按此长度预备并充填根管,即刻拍摄X线片,观察并测量根管充填情况。结果:ProPex测量磨牙牙齿操作长度的准确率:A组86.8%,B组96.2%,C组85.8%。结论:ProPex可以比较准确地测量磨牙牙齿操作长度。 AIM:To evaluate and analyze the accuracy of a new apex locator-ProPex in molar working length measurement. METHODS:Three hundred and eighty three root canals from 116 patients( 130 molars) were divide into 3 groups:group A(91 root canals from 30 molars) which needed retreatment because of underfilling;group B (130 root canals from 46 molars) which required intentional pulpectomy because of restorative and fixed prosthetic reasons;group C ( 162 root canals from 54 molars) which was undergoing chronic apical periodontitis. Working length of each root canal was measured by ProPex, and instrumentation and obturation were performed according to the working length. RESULTS:The accuracy of ProPex in molar working length measurement in the 3 groups was 86.8% ,96.2% and 85.8%. CONCLUSION:ProPex is relatively accurate in molar working length measurement.
出处 《牙体牙髓牙周病学杂志》 CAS 2005年第11期621-623,共3页 Chinese Journal of Conservative Dentistry
关键词 PROPEX 根管测量仪 磨牙 牙齿操作长度 ProPex apex loeator molar working length
  • 相关文献

参考文献5

  • 1林正梅,韦曦,彭思敏,刘建伟,凌征宇.Root ZX根尖定位仪在根管治疗中的应用[J].新医学,2001,32(11):666-667. 被引量:2
  • 2于晓霞,欧汝强,宋斌.Root ZX根尖定位仪对根管充填质量的影响[J].华中科技大学学报(医学版),2004,33(4):509-511. 被引量:2
  • 3Kovacevic M,Tamarut T.Influence of the concentration of ions and foramen diamerer on the accuracy of electronic root canal length measurement-an experimental study[J].J Endodon,1993,24(5):346-351.
  • 4Tamarut T,Kovacevic M,Uhac L.Detection of a transitional ion concentration zone during electronic measurement of root canal length:a study in vitro[J].Inter Endo J,2000,33(4):374-380.
  • 5Gorodon MPJ,Chandler NP.Electronic apex locators[J].Int Endod J,2004,37(7):425-437.

二级参考文献6

  • 1樊明文主编.牙体牙髓病学.北京:人民卫生出版社,2001.249,290
  • 2Pagavino G, Diamante D, Marri Metal. Localization of the apical foramen using the newest electronic instruments stereomicroscopy and SEM. Minerva Stomatol,1995, 44: 499
  • 3Shabahang S, Goon W W, Gluskin A H. An in vivo evaluation of Root ZX electronic apex locator. J Endod,1996, 22:616
  • 4Ibarrola J L, Chapman B L, Howard J H et al. Effect of preflaring on Root ZX apex locators. J Endod, 1999,29: 625
  • 5彭彬,雷芳,程勇,范兵.试尖对根管充填质量的影响——附1500例Digora图像分析[J].口腔医学纵横,2000,16(1):3-6. 被引量:136
  • 6王宏青,仲维剑,毕文翔,韩文利,董秀娥.根管长度电测法准确性的RVG片评价[J].口腔医学纵横,2001,17(3):201-202. 被引量:12