摘要
介绍了除湿转轮的性能测试原理与方法,重点讨论了湿度测量方法对测量结果不确定性的影响,同时分析了流量仪表精度对性能测试的影响。介绍了测试中的若干细节问题并给出了一个测试实例。
Presents the principles and methods involved in dehumidification capacity measurement of the desiccant wheel. Mainly discusses the influence of humidity measurement method on the uncertainty of final results. Analyses the effect of flowmeter accuracy on dehumidification capacity measurement. Presents several measurement details and an example.
出处
《暖通空调》
北大核心
2005年第11期63-66,共4页
Heating Ventilating & Air Conditioning
基金
上海市科委资助项目(编号:023012005)
关键词
除湿转轮
湿度测试
不确定度
误差分析
desiccant wheel, humidity measurement, uncertainty, error analysis