期刊文献+

一种高温空气湿度测量的方法 被引量:1

Method to measure humidity of high temperature air
下载PDF
导出
摘要 基于能量平衡及质量平衡,提出了一种通过冷、热风混合测量高温空气湿度的方法。该方法通过温度传感器对冷风、混风的干湿球温度及被测高温空气干球温度进行测量,利用湿空气热力性质关系计算被测高温空气的湿度及各状态参数,也可由常规仪表对高温空气湿度进行测量。该方法具有测量简单、精度高、测量成本低、易于实现的优点。运用误差传递理论对该方法的合成误差进行了计算,结果表明,测量高温低湿(t≤140℃,φ≤15%)的空气湿度,其测量精度可达到±0·5%。 Based on the energy and mass balance principles, presents a new method to measure the humidity of high temperature air by mixing cold and hot air in which the dry and wet bulb temperature of the cold air and mixed air and the dry bulb temperature of high temperature air are measured by temperature sensors, then the humidity and other parameters of high temperature air can be found by the thermodynamic relationship. And the humidity can also be measured conventionally. The method has the advantages of easy measurement, high precision, low cost and easy realization. Calculates and analyses the integrated error based on the error transfer theory. The result shows that the precision of relative humidity for the high temperature(up to 140℃ ) and low humidity(up to 15%) air is within ± 0.5% by the proposed method.
机构地区 清华大学
出处 《暖通空调》 北大核心 2005年第11期122-127,共6页 Heating Ventilating & Air Conditioning
关键词 高温空气 湿度测量 测量误差 混风比 high temperature air, humidity measurement, measurement error, mixing ratio
  • 相关文献

参考文献10

  • 1Humidity Measurement Technology. http://www.testo, de/US/lig/ upload/mwmlus_1034594054 7 50_1.pdf. 2004.
  • 2Technical report: state of the art of sensors. Galileo Ferraris Istituto Elettrotecnico Nazionale, CHE-TRIEN-0001,2001.1 - 9.
  • 3程起范.空气湿度及其测量方法[J].辽宁气象,1996(4):36-36. 被引量:3
  • 4彭哲方.气体湿度测量误差分析[J].广东第二师范学院学报,1995,26(2):48-53. 被引量:2
  • 5Nguyen Thi Thu Ha, Dao Khac An, Phan Viet Phong, et al. Study and performance of humidity sensor based on the mechanical-optoelectronic principle for the measurement and control of humidity in storehouses. Sensors and Actuators, 2000, 66 (B) .. 200-202.
  • 6龙庆华.湿敏电容及湿度测量仪表[J].自动化与仪器仪表,1999(3):44-46. 被引量:3
  • 7Luijten C C M, van Dongen M E H, Stormbom L E.Pressure influence in capacitive humidity measurement.Sensors and Actuators, 1998,49 (B) : 279 - 282.
  • 8Maximino Bedoya, Guillermo Orellana, Moreno Bondi. Fluorescent optosensor for humidity measurements in air. Helvetica Chimica Acta, 2001,84: 2628 - 2639.
  • 9.EE29/EE31多功能温湿度变送器[EB/OL].http://www.bjpride.com/product_E+E_2.html.,2004.
  • 10张子慧.热工测量与自动调节[M].北京:中国建筑工业出版社,1982.59-61.

二级参考文献5

  • 1陈天钧,叶穗红.集散控制系统中的通讯设计[J].华南师范大学学报(自然科学版),1997,29(1):20-24. 被引量:1
  • 2张丙新.潘纳梅曲克斯公司仪器介绍-氧化铝湿度计和超声不皮流量计性能介绍[J].PANAMETRICS,1989,:16-17.
  • 3龙庆华.温湿度计算机自动监测网络系统[J].华南师范大学学报,1995,3:13-13.
  • 4[]P·R·贝文顿 著,仇维礼,徐根兴,赵恩广等.数据处理和误差分析[M]知识出版社,1986.
  • 5中央气象局.湿度查算表[M]气象出版社,1980.

共引文献5

同被引文献12

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部