摘要
分析经长期随诊脊柱侧凸术后矫正度丢失的程度及原因。142例脊柱侧凸采用后路器械矫正固定,86例随诊6个月~8年6个月(平均3年4个月),术前、术后及随诊的X线片对比,分析丢失度与侧凸类型、年龄、内固定种类等之间的关系。28例(32.5%)丢失度大于15°,丢失度与年龄、侧凸类型无明显关系,而与内固定节段的选择、内固定种类及融合技术明显相关。正确选择内固定种类及融合节段,提高融合技术,减少假关节及脱钩的发生率,是长期维持脊柱侧凸术后矫正度的关键。
Theauthorsanalyseathecausesoflossofcorractionangleofscoliosisfollowingposteri-orspinalinstrumentalfixationandfusionin26caseswithafolow-upforanaverageof3yearsand4months..Thepreoperative,postoperativeandthefolow-upX-rayfilmswerecomparedinordertoeluci-datetherelationshipbetweenthecausesoflossofcorrectionangleandthescoliotictypeandageatthetimeofsurgeryaswelasthelevelsoffixationandfusion.28cases(32.6%)hadlossofcorectionformorethan15degrees.Therelationshipbetweenage,scoliotictypeandthelossofcorectionanglewasnon-significant,however,thelaterwassignificantbetweentheselectionofsegmentalleveloffixation,theinternalfixationinstrumentation,andthetechniqueoffusion.Thekeypointsforthemaintenanceofthecorrectedpositionforlong-termareproperselectionoffixationandtheleveloffusion.,improve-mentofthetechniqueoffusion,andthereductionoftheincidencesofpseudoarthrosisandhookdis-lodgement.
出处
《中华骨科杂志》
CAS
CSCD
北大核心
1996年第6期344-347,共4页
Chinese Journal of Orthopaedics
关键词
脊柱侧凸
矫正度丢失
外科手术
ScolioisDossofcorrectionPosterinstrumentation