摘要
目的 研究脑深部电刺激(DBS)冶疗帕金森病的手术方法和疗效。方法 对具有双侧症状的46例原发性帕金森病患者进行同期双侧丘脑底核(STN)电刺激术治疗,采用MRI扫描结合术中微电极记录技术进行靶点定位,术前、术后UPDRS运动评分评价手术疗效。结果 全部46例帕金森病患者术后震颤、僵直及行动迟缓均有不同程度改善,UPDRS评分“关”状态平均改评善率为635%;“开”状态平均改善率为26.4%。术后随访1年症状仍有持续性改善,未发现任何严重永久性并发症。结论 脑深部电刺激术可明显改善帕金森病的主要症状,是目前治疗帕金森病的最佳方法。
Objective: to investigate the effeeting or deep brain stimulation in the treatment of Parkinson's disease. Methodss: 46 patients with Parkinson's disease underwent the bilateral surgery of STN deep brain stimulation. Using MRI scan for imaging-based anatomic targel and target, contrasting the score of UPDRS between pre-operalion and post-operation to evaluate the effect. Results: All the patients have the obviously improvement to the main symptom (including tremor rigidity and dyskinesia), Scores of UPDRS descended significantly after DBS(P〈0.01), the improvement rate are separately 63.5% in the “off” states and 26.4% in the “on” state. The symptom continuous improved and no severe complication were found follow-up visit one year after operation. Conclusions DBS can obviously improve the main symptoms of Parkinson disease, and is the best way in the treatment of Parkinson disease.
出处
《中国医疗器械信息》
2005年第8期9-11,共3页
China Medical Device Information