期刊文献+

寰枢椎后路经关节螺钉内固定治疗寰枢椎不稳定的生物力学及临床研究 被引量:7

Biomechanical and clinical study of atlantoaxial instability in posterior atlantoaxial transarticular screw fixation
原文传递
导出
摘要 目的评价寰枢椎后路经关节螺钉内固定术两种不同钉道的生物力学稳定性及疗效。方法在8例新鲜尸体标本依次轮流测试正常、Ⅱ型齿状突骨折行AO进钉点与改良进钉点两种后路钉道螺钉固定术模型三维运动范围,并在16例寰枢椎不稳定患者,采用枢椎下关节突下缘正中点为进钉点的方法行经关节螺钉固定及自体颗粒样松质骨植骨术。结果两种入钉方法均能明显减少寰枢关节的各向运动角度(P<0.01),但两者间差异无统计学意义(P>0.05)。经5~ 48个月随访,16例患者寰枢关节稳定性均获得恢复与骨融合,无并发症。结论新入钉点解剖标志明确,钉道长,能提供牢固地固定,并发症发生率低。 Objective To determine the biomechanical stability of C1-2 and clinical effects after instrumentation with two screw trajectory in posterior atlantoaxial transarticular screw fixation. Methods The three-dimensional motions of C1 relative to C2 were measured in 8 human cadaveric specimens, which was by turns under 4 models: nomal, 11 odontoid fractures, with AO or modified posterior atlantoaxial transarticular screw fixation respectively. The 16 atlantoaxial instability patients were treated with posterior C1-C2 transarticular screws and the autogenous granulated cancellous bone graft, in which the screw entry point was the center of lower edge on axis processus articularis inferior. Results Two inserting methods of posterior atlantoaxial transarticular screw fixation significantly decreased motion in all directions. There was generally no significant difference in the amount of motion among the two screw trajectory. During a follow-up of 5-48 months, atlantoaxial instability was restored satisfactorily in 16 patients with no complication and bone fusion was obtained. Conclusion The bony landmark of the new entry point was definite, which can provide the long length of screw trajectory and the rigid fixation with low complication rate.
出处 《中华实验外科杂志》 CAS CSCD 北大核心 2005年第12期1530-1532,共3页 Chinese Journal of Experimental Surgery
关键词 寰枢椎 固定术 三维 骨融合 生物力学 关节螺钉 Atlantoaxial Fixation Three-dimensional Bone fusion Biomechanlcal
  • 相关文献

参考文献7

  • 1Dickman CA, Foley KT, Sonntag VK, et al. Carmulated screws for odoutoid screw fixation and atlantoaxlal transarticular screw fixation:Technical note. J Neurosurg, 1995, 83 : 1095-1100.
  • 2Eleraky MA, Masferrer R,Sonntag VK. Posterior atlantoaxial facet screw fixation in rheumatoid arthritis. J Neurosurg, 1998, 89 : 8-12.
  • 3Grob D, Jeanneret B, Aebi M, et al. Atlanto-axial fusion with transarticular screw fixation.J Bone Joint Surg Br, 1991, 73:972-976.
  • 4McGuire RA, Harkey HL. Modification of technique and results of atlantoaxial transfacet stabilization. Orthopedics, 1995, 18 : 1029-1032.
  • 5Magerl F, Seeman P. Stable posterior fusion of the atlas and axis by transarticular screw fixatio, In KehrP;WeidnerA, (eds). Cervical Spine Ⅰ . New York:Springer verlag, 1987, 322-326.
  • 6Paramore CG, Dickman CA, Sonntag VK. The anatomical suitability of the Ci-2 complex for transarticular screw fixation. J Neurosurg, 1996,85: 221-224.
  • 7Wright NW, Lauryssen C. Vertebral artery injury in C1-2 transarfieular screw fLxation:results of survery of the AANS/CNS section on disorders of the spine and peripheral nerves. J Neurosurg, 1998, 88:634-640.

同被引文献78

引证文献7

二级引证文献21