期刊文献+

大口径元件反射率的镜面扫描精密测量系统 被引量:6

Precise measurement system for reflectivity scanning of large aperture components
下载PDF
导出
摘要 为了测量高功率激光传输系统中大口径高反射率元件,研制了一种镜面扫描的精密测量系统。介绍了该系统的结构及其工作原理,分析了影响系统测量精度的因素,理论上估算的测量精度为2×10-5。在直腔下对该系统的性能进行了实验测试,分析表明,系统的测量不确定度优于2.052 28×10-5,最大测量误差为3.554 04×10-5,与理论预计结果吻合较好。对大口径元件进行的多次实验扫描测试,结果显示,镀膜加工误差导致反射率分布是关于镜面中心呈旋转对称。该系统的使用大大简化了元件表面反射率分布的测量。 A precise measurement system of high reflectivity for scanning large aperture components in high power laser system is developed. The structure and working principle of this system are introduced, and those factors that influence its metrical precision are analyzed. According to theoretic analysis, precision of this measurement system is 2×10^-5. Experimental measurements for capability of this system were carried out, which show that RMS of measurement in linear cavity is better than 2. 05228×10^-5. Results give that the biggest measurement error is 3.55404×10^-5, which is in good agreement with the analysis. Scanning experimental measurements for large aperture components were also carried out. Results show that distribution of reflectivity is circular symmetric about the center of mirrors, which is caused by machining error in the course of film plating. The reflectivity measurement system makes it very easy to measure reflectivity distribution on large aperture components.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2005年第11期1601-1604,共4页 High Power Laser and Particle Beams
基金 中国工程物理研究院基金资助课题(20030442)
关键词 光学测量 反射率 光腔衰荡 测量精度 大口径 Optical measurement Reflectivity Cavity ring-down Metrical precision Large aperture
  • 相关文献

参考文献10

二级参考文献21

  • 1易亨瑜,吕百达,彭勇,刘盛林.探测器孔径大小对衰荡腔测量精度的影响[J].激光技术,2004,28(3):231-233. 被引量:16
  • 2易亨瑜,吕百达,胡晓阳,田小强,张凯.腔长失调对光腔衰荡法测量精度的影响[J].强激光与粒子束,2004,16(8):993-996. 被引量:25
  • 3桑凤亭,顾成洲,逄景科,李明盛,李富岭,孙以珠,金玉奇,庄琦.连续波氧碘化学激光器的实验研究[J].强激光与粒子束,1993,5(3):389-393. 被引量:3
  • 4[1]OKeefe A,G Decon D A.Cavty Ringdown optical spectromater for absorption measurements using pulsed laser sources[J].Pre. Rci.Instrum,1988,59(12): 2544-2550.
  • 5[2]Rominini D,Kechonov A A,Sagleghi N.CW cavity ringdown spectros copy[J].Chem.Phys.Lett,1997,264:816-821.
  • 6[3]Yariv A.Quantum Electronices[M].New York:Wile y & Sons,1988.147-149.
  • 7[1]ANDERSON D Z,FRISCH J C,MASSER C S.Mirror reflectorbased on optical cavity decay time [J].Appl Opt,1984(23):1238~1242.
  • 8[5]KOGELNIK H.Coupling and conversion coefficients for opticalmodes [J].Symposium on Quasi-Optics,1964,8~10(6):333.
  • 9易亨瑜 彭勇 胡晓阳.衰荡腔腔长失调实验分析[J].中国激光,2003,31(0):486-486.
  • 10ANDERSON D Z,FRISCH J C,MASSER C S. Mirror reflector based on optical cavity decay time [ J]. Appl Opt, 1984,23 (8):1238-1242.

共引文献58

同被引文献74

引证文献6

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部