摘要
通过分析低温水系统运行现状及存在的问题,提出确定6#机投运与停运条件、提高1#低温水温度、改造换热流程及增加热水换热负荷等优化运行方案。
Through analyzing the present situations and problems of low-temperature water system, Put forward some plans of optimization such as determining the condition of setting into or out of operation of No.6 steam turbine;raising the temperature of No.1 low-temperature water;rebuilding the process of heat exchange;increasing the load of hot water.
出处
《能源研究与利用》
2005年第6期43-46,共4页
Energy Research & Utilization
关键词
低温水
换热
优化
low-temperature water
heat exchange
optimization