摘要
目的:探讨机械通气治疗急性中毒所致呼吸衰竭的疗效。方法:回顾性分析28例急性中毒所致的呼吸衰竭患者机械通气的临床资料。结果:治愈25例,死亡3例。上机时间10h~9d,平均49.6h。与机械通气相关的并发症有肺部感染21例,低血压3例。结论:机械通气是治疗急性中毒所致呼吸衰竭的有效方法。
Objective:To investigate the effect of mechanical ventilation on the patients with respiratory failure caused by acute poisoning. Methods:28 patients with respiratory failure as a result of acute poisoning treated by mechanical ventilation were analyzed retrospectively. Results:25 cases were cured and 3 cases were died. The time of mechanical ventilation were from 10 hrs to 9 days, the average time was 49.6 hrs. The complication associated with mechanical ventilation was that 21 cases suffered from pneumonia and 3 cases had low blood pressure. Conclusion: Mechanical ventilation on the case with respiratory failure as a result of acute poisoning is effective.
出处
《岭南急诊医学杂志》
2005年第4期253-254,共2页
Lingnan Journal of Emergency Medicine
关键词
机械通气
急性中毒
呼吸衰竭
mechanical ventilation
acute poisoning
respiratory failure