摘要
目的:建立以旋光度测定法测定硫酸阿米卡星注射液中主药含量的方法.方法:以水为溶剂,用1dm测定管测定硫酸阿米卡星注射液在589.4nm波长下的旋光度.结果:阿米卡星检测浓度在1~20mg/ml范围内与旋光度线性关系良好(r=0.9999),平均加样回收率为99.8%(RSD=0.89%,n=5).结论:本方法简便、快速、准确,可用于本品的质量控制.
OBJECTIVE: To establish polarimetry for the assaying of the principal agent in amikacin sulfate injection. METHODS: The optical rotation of amikacin sulfate was determined with ldm determination tube with water as solvent at a wavelength of 589.4nm.RESULTS: The linear range of amikacin was 1-20mg/ml(r = 0.9 999); The average recovery rate was 99.8% (RSD = 0.89% ,n = 5).CONCLUSION:The method is simple,fast and accurate,and it can be used for the quality control of amikacin sulfate injection.
出处
《中国药房》
CAS
CSCD
北大核心
2005年第23期1819-1820,共2页
China Pharmacy