用光腔衰荡光谱法判断钕玻璃体损伤的产生 被引量:1

Determining Damage inside Nd-glass with Cavity Ring-Down Spectroscopy Method
下载PDF
导出
摘要 运用光腔衰荡光谱技术测量钕玻璃在激光辐照下其透过率的变化,判断出钕玻璃体损伤的产生。实验采用直腔型衰荡光腔,通过检测钕玻璃在强激光辐照下产生应力时其透过率的变化,测试出了钕玻璃在强激光辐照下产生体损伤的激光能量密度。该测试方法灵敏度高,且对测试元件无破坏作用。 The transmittivity of Nd-glass will vary when the high power laser radiates. It can be used to determine damage inside the Nd-glass by using the cavity ring-down spectroscopy method. The linear ring-down cavity is used in the experiment. The variety of Nd-glass's transmittivity is determined. The laser energy density is determined when the damage occurred inside the Nd-glass. The method is sensitive and does not destruct influence to the sample.
出处 《光学与光电技术》 2005年第6期54-56,60,共4页 Optics & Optoelectronic Technology
关键词 光腔衰荡光谱 钕玻璃 透过率 体损伤 激光能量密度 cavity ring-down spectroscopy Nd-glass transmittivity inside-damage laser energy density
  • 相关文献

参考文献4

  • 1[1]A O'Keefe, D A G Decon. Cavity ring-down optical spectrometer for absorption measurements using pulsed laser sources[J]. Rev. Sci. Instru., 1988, 59(12): 2544~2551
  • 2[2]D Rminini, A A Kechonov, N Sagleghi. CW cavity ringdown spectroscopy[J]. Chem. Phys. Lett, 1997, 264:816~821
  • 3[3]Dongxu Dai, Fuge Sun, Lu Kang, et al. A high rep. rate real time measurement of cavity ring down spectroscopy[J].Chinese J. Chem. Phys., 1997, 10(6): 481~486
  • 4赵宏太,柳晓军,王谨,曹俊文,赵志,詹明生.用光腔衰荡测定腔镜及镜片的反射率[J].光电子.激光,2001,12(1):71-73. 被引量:25

二级参考文献3

  • 1[1]OKeefe A,G Decon D A.Cavty Ringdown optical spectromater for absorption measurements using pulsed laser sources[J].Pre. Rci.Instrum,1988,59(12): 2544-2550.
  • 2[2]Rominini D,Kechonov A A,Sagleghi N.CW cavity ringdown spectros copy[J].Chem.Phys.Lett,1997,264:816-821.
  • 3[3]Yariv A.Quantum Electronices[M].New York:Wile y & Sons,1988.147-149.