期刊文献+

PF-1型旧氟离子选择电极的再利用 被引量:1

Reuse of PF-1 Type of Old Fluorine Ion Selected Electrode
下载PDF
导出
摘要 基于氟离子选择电极对OH-的敏感性,提出了一种用NaOH溶液活化再生旧氟离子选择电极的方法,实验结果表明:NaOH溶液浓度在0.005~0.05mol·L-1,活化时间在30~35min为宜.将活化的电极用于样品分析及加标回收率的测定,结果令人满意. A method of activating and regenerating old fluorine ion selected electrode by means of NaOH solution has been pointed out based on fluorine ion selected electrode. The result of experiment shows : the cleasity of NaOH solution is 0.005 - 0.05 mol·l^ - 1, activating time within 30-35 min. will be suitable. The analysis of the sample of activating electrod and the determination of recollecting rate is sample of activating electrode and the determination of recollecting rate is satifactory.
出处 《景德镇高专学报》 2005年第4期42-43,共2页 Jingdezhen Comprehensive College Journal
关键词 PF-1型氟离子选择电极 TISAB 活化时间 离子选择电极 PF - 1 fluorine ion selected electrode TISAB activting time ion selected electrode
  • 相关文献

同被引文献1

引证文献1

二级引证文献1

相关作者