摘要 目的运用计算机流体力学(CFD)分析评价XZ-Ⅱ型血泵的溶血情况。方法将XZ-Ⅱ型血泵的主体血泵CAD二维图采用Solid Work三维造型软件过渡生成几何数据文件,然后采用Fluent6.1流场分析软件做计算和流场分析,同时进行体外溶血实验。结果CFD显示,在叶轮入口、叶轮的端面和叶轮与导流叶片间,有较大的剪切率产生,且后者引起流动分离,从而影响了出口流速和流动的稳定性;体外溶血实验示,标准溶血指数(NIH)为(0.0473±0.0165)mg/dL。结论采用湍流模型和非牛顿流体粘性系数公式进行CFD对血泵溶血情况的分析,基本反映了血泵内部血流特性,XZ-Ⅱ型血泵在叶轮入口、叶轮端面和导流叶片等处产生高剪切力,应进行相应的改进。 Objective To evaluate hemolysis of XZ-H axial flow blood pump by computational fluid dynamics (CFD) analysis. Method General flow patterns, shear stress loading were calculated by means of CFD. In vitro hemolysis tests were performed. Result Shear stress was increased at the inlet, edge and end point of the impeller. NIH was (0.0473 ± 0.0165) mg/dL. Conclusion CFD may be a good method to evaluate hemolysis of blood pump. The impeller of XZ- H axial flow blood pump should be improved further.
出处 《北京生物医学工程》 2005年第6期452-453,467,共3页 Beijing Biomedical Engineering
基金 北京市科技新星(HO20821490130) 北京市自然科学基金(30420086)资助
关键词 溶血 血泵 计算流体力学分析 hemolysis blood pump computational fluid dynamics
  • 相关文献

参考文献3

  • 1Arora D, Behr M, Pasquali M. A tensor-based measure for estimating blood damage. Artif Organs, 2004, 28 ( 11 ): 1002 -1015.
  • 2吴广辉,蔺嫦燕,李冰一,王景.XZ-ⅡA型轴流血泵的研制及体外流体实验[J].北京生物医学工程,2004,23(3):215-217. 被引量:9
  • 3Yamane T, Asztalos B, Nishida M, et al. Flow visualization as a complementary tool to hemolysis testingin the development of centrifugal blood pump. Artif Organs, 1998, 22 (5): 375 - 380.

二级参考文献4

  • 1蔺嫦燕,孙衍庆,董培青,魏文宁,王建华,王秀敏.微型血泵的研制及其模拟实验研究[J].中国生物医学工程学报,1997,16(1):64-69. 被引量:18
  • 2[2]Eiji okamoto, Takuya Hashimoto. Blood compatible design of a pulsatile blood pump using computational fluid dynamics and computer-aided design and manufacturing technology. Artificial Organs, 2003, 27 (1):61 - 67
  • 3[3]Jorn Apel, Frank Nendal. Computational fluid dynamics and experimental validation of a microaxial blood pump. ASAIO, 2003, 20: 552- 557
  • 4蔺嫦燕,李冰一,陈力争,姜以岭,王景,孙衍庆,侯晓彤.Ⅱ型叶片轴流血泵的研制及体外流量实验[J].中国生物医学工程学报,2002,21(2):149-153. 被引量:10

共引文献8

同被引文献26

引证文献6

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部