摘要
某工业厂房建成后使用仅几年,地面就出现大面积的隆起开裂,部分设备基础也产生倾斜,为查明原因,对该厂房进行了全面检测。根据现场调查、检测和试验结果,对引起该厂房地面隆起开裂的原因进行了分析,给出了分析结论与处理建议,供类似工程参考。
The ground of an industrial workshop bulged and cracked in large scale during only several years after it was completed, and some equipment foundations also inclined. In order to find out the reason, the workshop had been inspected completely. According to the field inspections and experimental results, the reason why the ground bulged and cracked is analyzed, and conclusions and suggestions are made, which can provide references for other similar engineering.
出处
《四川建筑科学研究》
北大核心
2005年第6期72-75,共4页
Sichuan Building Science
关键词
隆起
开裂
钢渣
稳定性
腐蚀
bulging
cracking
steel slag
stability
erosion