摘要
氧瓶燃烧法以硝酸镧标准溶液做滴定剂,苏木精为指示剂,测定棉籽中的总磷。该方法不受硫的干扰,相对标准偏差为0.3%~5.7%,检知量为0.049mg,回收率为99.57%~103.42%,适合于一般实验室测定有机磷样品。
The oxygen-flask cormbustion method is used to determine the total phosphorus in cotton seed using lanthanum nitrate as titrant and haematoxylin as indicator. It is not interfered by sulphur. The relative standard deviation is 0. 3% ̄5. 7%, the detection limit is 0. 049mg, th.e recovery is 99. 57% ̄103. 42%. This mathod can be applied to the determination of organic. phosphorus samples in common laboratory.
关键词
氧瓶燃烧
苏木精
棉籽
磷
有机分析
oxygen-flask combustion
haematoxylin
lanthanum nitrate
determination of total phosphorus in cotton seed