期刊文献+

自来水管道漏水定点探测系统中数据处理的实现

Realization of Data Processing in the Detecting System of the Fixation Leakage Point of the Tap Water Pipeline
下载PDF
导出
摘要 在介绍相关渗漏检测仪器的工作原理和分析互相关理论的基础上,提出了一种基于数字处理器(DSP)TMS320VC5402芯片实现相关分析的方法,给出了仪器数据处理部分硬件设计电路和相应软件算法及流程图。实验证明:整个仪器的测量误差在0.5 m内,达到了预期要求。 By introducing the main principle of the leakage detecting instrument and analyzing the correlative theory, this paper put forward a method for realizing correlative analyses with one type of digital signal processor(DSP)chip TMS320VC_5402, and inla'ouduced the hardware of data processed part of the instrument, the software arithmetic and the flow chart, After testing, the error of the whole instrument was known to be 0.5 meter,which has satisfied our expected need.
出处 《管道技术与设备》 CAS 2005年第6期17-18,28,共3页 Pipeline Technique and Equipment
关键词 地下管道 渗漏 相关分析 DSP SPI underground pipeline leakage correlative analyzing technology DSP SPI
  • 相关文献

参考文献1

二级参考文献1

  • 1李哲英 骆丽 刘元盛.DSP基础理论与应用技术[M].北京:北京航空航天大学出版社,2002.99-103.

共引文献1