期刊文献+

焦炭塔塔顶大油气线应力分析及改造

Stress analysis and Reform of Oil-gas Pipeline on Top of Coke Tower
下载PDF
导出
摘要 荆门石化总厂焦化装置焦炭塔塔顶大油气线在运行期间,多次出现险情,应力超标问题严重。针对该大油气线现有配管方案进 行深入分析,得出该方案本身就存在应力超标的缺陷,从而设计了全新的配管方案。经过近1年的生产实践证明,新配管方案彻底解决了应力 超标的问题,消除了威胁安全生产的重大隐患。 Under working condition, several risk situations, the stress in the pipe exceeded limit, have appeared in the large diameter of oil gas pipeline on the top of coke tower in coke eonstruction in Jingmen Petrochemical Plant. With respect of the current layout of the oil gas pipeline, the analysis showed this layout scheme caused of the phenomena of that stress exceeded limit. Therefore, a new layout scheme was de signed. After one years operation, it has been proved that this new layout scheme solved the problem of stress out of limit, and this hidden danger has been removed.
作者 张海清
出处 《化工设备与管道》 CAS 2005年第6期30-32,共3页 Process Equipment & Piping
关键词 焦炭塔 塔顶大油气线 应力分析 改造 coke tower, large oil gas pipeline on top of tower, stress analysis, reform