采用二氧化氯对含氰农药废水进行处理,在ClO2/CN-为3.5~4.5(质量比),pH值为11.5,搅拌反应2 h的条件下,对于氰化物浓度(以CN-计)60~80 ng·L-1的废水氰化物的去除率达97 %以上.实例表明,利用二氧化氯处理含氰农药废水,具有去除效率高,运行稳定,操作安全方便,自动化程度高等优点.
ClO2 was applied to treat the pesticide wastewater contained cyanogens. When the mass ratio of ClO2 and CN was 3.5-4.5, pH was 11.5 ,the cyanide removal rate of wastewater with cyanide mass concentration 60-80 ng/L(counted by CN^-) was more than 97% after 2h stir reaction. The treatment results showed that this method had higher removal rate, steady running, safety and easy operation, high automation degree, and so on.
出处
《化工技术与开发》
CAS
2005年第6期52-53,24,共3页
Technology & Development of Chemical Industry
关键词
氰化物
二氧化氯
含氰农药废水
废水处理
cyanide
chlorinedioxide
pesticide wastewater contained cyanogens
wastewater treatment