摘要 通过对二滩电厂推力/下导油槽油雾产生原因的分析和油雾治理过程的介绍,阐述了大型半伞式发电机组 推力油槽油雾防治的一般方法。 The 550 MW hydroelectric generating sets of Ertan Hydropower Plant were designed and made by contract to Hydro GE (Canada). The oil mist appeared after the oil spun-off from the thrust/lower-guide bearing had been dealt with. This paper analyzes the cause of forming mist from oil sump of the thrust/lower-guide bearing, introduces the measures against oil mist for the units. The general approaches to prevent and control oil mist for large semi-umbrella hydroelectric generating sets are proposed.