摘要
在298.15 K下,分别测定了5A和VP800分子筛的静态吸附等温线和动态穿透曲线,并根据动态穿透曲线分别计算出5A和VP800分子筛的氮氧分离系数。研究发现,VP800分子筛的氮氧分离选择性明显高于5A分子筛。从动态吸附的结果来看,VP800有一个最优的吸附分离压力。
The adsorption isotherms and dynamic breakthrough curves of N2 and O2 on 5A and VP800 molecular sieves were measured at 298. 15 K. The separation factor of N2/O2 was calculated in terms of the breakthrough curves of N2 and O2. The results showed that the separation selectivity of N2 and O2 on VP800 molecular sieve was higher than that on 5A molecular sieve. Moreover, VP800 molecular sieve was of a suitable pressure for adsorption separation of N2 and O2.
出处
《青岛科技大学学报(自然科学版)》
CAS
2005年第6期497-499,共3页
Journal of Qingdao University of Science and Technology:Natural Science Edition
关键词
5A分子筛
VP800分子筛
吸附等温线
穿透曲线
分离系数
5A molecular sieve
VP800 molecular sieve
adsorption isotherm
breakthrough curve
separation factor