期刊文献+

两种体外细胞毒性检测方法的比较研究 被引量:16

Study on Comparison of Two in Vitro Cytotoxicity Tests
下载PDF
导出
摘要 目的比较两种常用的细胞毒性检测方法在医疗器械生物学评价中的相关性.方法分别采用MTT比色法和细胞增殖度法,在37℃条件下,将五种医疗器械/生物材料的浸提液分别与小鼠成纤维细胞(L-929)接触2天和2,4,7天,比较材料对细胞的毒性影响.结果 5种不同的材料浸提液分别表现出不同程度的细胞毒性反应(0~2级).将MTT比色法与细胞增殖度法(2天)的实验数据进行相关性分析,显示两者之间具有良好的相关性(R=0.977).结论 MTT比色法由于其检测所需的细胞量相对较少,试验步骤相对简便、检测周期短,因此具有一定的优越性,是个值得推荐的细胞毒性检测方法. Objective To study the relativity between two in vitro cytotoxicity test which used in biological evaluation of the medical device. Method The extracts of 5 kinds of medical devices/biomaterials were contacted with the L- 929 cells for 2days and 2,4,7days respectively at 37 ℃ by the MTT assay and proliferation test, compared the cytotoxic reaction. Results Under the condition of this study, 5 kinds of medical devices/biomaterials showed a different grades of the cytotoxicity (02grades). the results of MTT assay compared with it of cell proliferation test (2 days) showed a good relativity( R = 0.977). Conclusion when compared with the cell proliferation test, MTT assay need less amount of the cells, be more simple and shorter, it is worth to evaluate the reaction of cytotoxicity for the medical devices/biomaterials.
出处 《上海生物医学工程》 2005年第4期205-207,共3页 Shanghai Journal of Biomedical Engineering
基金 上海市重点学科(特色学科)建设项目资助(T0202)
关键词 体外细胞 细胞毒性 检测方法 细胞增殖度法 MTT比色法 In vitro Cytotoxicity MTT assay cell proliferation test
  • 相关文献

参考文献8

  • 1Harmand MF.In vitro study of biodegradation of Co-Cr alloy using a human cell mode.J Biomater Sci Polym Ed,1995,6(9):809.
  • 2ISO 10993-1:2003,Biological evaluation of medical devices-Part 1:Evaluation and testing.
  • 3ISO 10993-5:1999,Biological evaluation of medical devices-Part 5:Tests for in vitro cytotoxicity.
  • 4贾文英,史弘道.细胞毒性试验评价医用装置生物相容性的研究概况[J].实用美容整形外科杂志,2001,12(5):253-255. 被引量:22
  • 5ISO 10993-12:2002,Biological evaluation of medical devices-Part 12:Sample preparation and reference materials.
  • 6GB/T16175-1996.医用有机硅材料生物学评价试验方法.[S].,..
  • 7奚延裴.组织工程医疗产品的安全性评价[J].现代康复,2001,5(6):13-13.
  • 8孙皎,宁丽,顾国珍,钱芸芳,孟爱英.医用丝素蛋白皮肤再生膜的细胞相容性评价[J].生物医学工程学杂志,2000,17(4):393-395. 被引量:21

二级参考文献5

共引文献49

同被引文献182

引证文献16

二级引证文献89

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部