摘要
介绍了东方汽轮机厂生产的210MW供热抽汽机组轴封系统的工作原理及结构特点和调整运行注意事项,并针对在调试过程中发现的测量仪表偏差、低压轴封供汽温度失控、轴封供汽中断等问题,进行了详细的分析并提出相应的对策。
This article introduces operation principle and structure characteristic of gland seal system of 210MW extract turbine, presents consideration that should be pay attention during commissioning operation, and analyzes problem existing in commissioning, such as inaccurate meter measurement, temperature loss control of low pressure gland steam, and interruption of gland steam, This paper also gives some relevant countermeasures, whieh are important for improvement of design, installation and operation.
出处
《湖南电力》
2005年第6期36-39,共4页
Hunan Electric Power
关键词
汽封
原理及特点
调试
改进
steam-seal
principle
characteristic
commissioning
improvement