摘要 目的:探讨室性心律失常与心脏病的病因及临床相关因素的相关性。方法:对动态心电图检测出的908例室性 心律失常病例进行病因及临床相关因素分类,并进行分析。结果:在有、无器质性心脏疾病的患者中均可发生室性 心律失常,其发生率由多至少依次为冠心病、高血压、瓣膜病、心肌病、先心病、病因不明、病窦+房室传导阻滞 (SSS+AVB)、糖尿病,而相关因素中,室性心律失常的发生率依次为左室肥大、心功能损害及心房颤动。结论:动 态心电图监测能提高室性心律失常的检出率,有利于心脏病及心律失常的诊治,改善其预后。 Objective: To discuss the relation between ventricular arrhythmias (VA) and heart disease. Methods: A total of 908 cases with VA in dynamic electrocardiogram (DCG) were analyzed by causes of disease and clinical factors. Results: According VA incidence the correlate disease was coronary artery disease (45.70M), hypertension (30.62 % ), valvular disease (13.44 % ), myocardial disease, congenital heart disease, unknown causation, sick sinus syndrome +atrial ventricular block, diabetes mellitus (4.63%); the correlative clinical factor was left ventricular hypertrophy (62.28%), atrial fibrillation (24.78%), heart failure (11.34%) respectively. Conelasion : DCG can increases recognizing rate of VA, is helpful to treat heart disease and ventricular arrhythmia, thus improve the prognoses.
出处 《心血管康复医学杂志》 CAS 2005年第6期582-584,共3页 Chinese Journal of Cardiovascular Rehabilitation Medicine
关键词 心电描记术 便携式 心律失常 发病率 Electrocardiogram, dynamic Arrhythmias Incidence
  • 相关文献

参考文献7

二级参考文献20

  • 1马燕.非持续性室性心动过速患者心率变异分析[J].心血管康复医学杂志,1999,8(2):67-68. 被引量:7
  • 2Kohl P, Noble D. Mechanosensitive connective tissue: potential influence on heart rhythm[J]. Cardiovasc Res,1996,32:62-68.
  • 3Franze MR. Mechano-electric feedback in human heart[J]. Cardiovasc Res,1996,32:15-24.
  • 4Kiseleva I, Kamkin A, Wagner KD, et al. Mechanoelectric feedback after left ventricular infarction in rats[J]. Cardiovasc Res,2000,(45):370-378.
  • 5Takagi S, Miyazaki T, Moritani K, et al. Gadolinium suppresses stretch-induced increases in the differences in epicardial and endocardial monophasic action potential durations and ventricular arrhythmias in dogs[J]. Jpn Circ J,1999,63:296-302.
  • 6Chorro EJ, Canoves J, Guerrero J, et al. Opposite effects of myocardial stretch and verapamil on the complexity of ventricular fibrillatory pattern: an experimental study[J]. Pace,2000,23[ptⅠ]:1594-1603.
  • 7Reiter MJ, Landers M, Zetelaki Z, et al. Electrophysiological effects of acute dilatation in the isolated rabbit heart: cycle length-dependent effects on ventricular refractoriness and conduction velocity[J]. Circulation,1997,96:4050.
  • 8Lab MJ. Contraction-excitation feedback in myocardium: physiological basis and clinical relevance[J]. Circ Res,1982,50:757-766.
  • 9Lab MJ. Mechanosensitivity as an integrative system in heart: an audit[J]. Prog Biophys Mol Biol, 1999,71(1):7-27.