期刊文献+

流动注射在线膜分离预富集在原子光谱中的应用

FI On-line Membrane Separation/Preconcentration and Its Application in Atomic Spectrometry
下载PDF
导出
摘要 研究了IDAE(Iminodiaceticacid/ethylcelulose)膜的在线分离预富集环境水样品中痕量元素的流动注射分析系统。建立了将在线流动注射这一体系与火焰原子吸收、电感耦合等离子体原子发射光谱联用,通过计算机辅助采集数据点,实现天然水样品中痕量重金属元素Cd,Co,Cu,Pb,Mn,V,Ni等的在线分离预富集的原子光谱分析方法。本方法的测定速率达到30次/h,浓集倍数达20倍。同时我们还考察了体系的检出限、相对标准偏差、加标回收率、膜的动态容量和动态富集性能、富集效率、使用寿命等,取得了令人满意的结果。实验结果表明,流动注射分析(FIA)在线分离预富集比起微型柱分离来说,有许多优点,如:分析速度快、自动化程度高、操作简便、不易堵塞、寿命长、重现性好、样品的消耗量少等。IDAEC膜分离预富集与FIA-ICP-AES联用的体系,是一种极为方便,高效而且普遍适用,易于推广的测定环境水样品中痕量重金属元素的手段。 The iminodiacetic acid/ethyl cellulose(IDAEC) membrane was applied to the FI on-line separation and preconcentration for the trace elements in environmental waters. The system was copied with both AAS and ICP-AES. The optimization of the system was performed. The preconcentration factor of 20 could be reached. The asmple up-take rate is 30 per hour. The system developed in this work has the advantages of fast analysis, automatic operation, less asmple consumption.
出处 《抚顺石油学院学报》 1996年第3期81-85,共5页 Journal of Fushun Petroleum Institute
基金 国家自然科学基金
关键词 膜分离 流动流射 原子光谱 Flow injection Membrane separation Atomic spectrometry
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部