采用火灾烟气控制工程计算方法,设定较适合的火灾场景,对某中庭建筑排烟方式进行性能化分析,得出采取自然排烟方式的可行性建议,并确定了排烟设备的选型、数量和控制方式。
Based on fire smoke-control project calculating methods and the suitable fire scenarios, this paper introduces the performance - based analysis of ventilation design of one atrium building, concluding that natural exhaust ventilation is possible, and some suggestions of ventilation windows types, numbers and operation control methods and smoke control ventilation design performance-based analysis are also provided.
出处
《武警学院学报》
2005年第6期19-21,共3页
Journal of the Armed Police Academy
关键词
烟气控制
排烟设计
性能化分析
smoke control
ventilation design
performance-based analysis