摘要 应用新型电子器件及单片计算机,研制出一种高性能的氢清除法局部血流量测定仪;并设计了相应的计算机处理程序,自动采集氢清除曲线,用最小二乘法拟合曲线,根据拟合曲线计算出局部血流量。用该系统测定了大鼠纹状体脑血流量,拟合曲线与氢清除曲线基本上完全重合,拟合参数正确无误。血流仪设计合理,工作稳定、可靠。用微机自动对氢清除曲线进行数据采集、分析,提高了测量结果的准确性,并可及时得出实验结果。 A new instrument, furnished with hydrogen clearance technique for measuring local blood-flow, was designed by use of new electronic components and a microcontroller. The corresponding program was developed. The curve of hydrogen clearance was sampled automatically by microcomputer, fitted into an exponential function by least square method, and then the local blood-flow was calculated. The cerebral blood-flow in the rat's strlatum had been measured using the system. The fitted curve corresponds with the curve of hydrogen clearance and the obtained parameter was correct. The design of the instrument was reasonable. It can work reliably and stably. The calculated results are more accurate and they can be acquired more quickly, because the curve of hydrogen clearance is automatically sampled and analyzed by the microcomputer.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2005年第6期1148-1150,共3页 Journal of Biomedical Engineering
关键词 脑血流 氢清除法 数据采集 曲线拟合 微机 Cerebral blood-flow Hydrogen clearance technique Data sampling Curve fitting Microcomputer
  • 相关文献

参考文献5

二级参考文献4

  • 1包仕尧,中国神经精神疾病杂志,1987年,13卷,3期,133页
  • 2团体著者,简明化学手册,1980年
  • 3包仕尧,赵合庆,金世蓉,邵国富,章伯松,杜子威.氢清除法局部脑血流量测定(附13例脑梗塞动物模型局部脑血流量测定)[J]中国神经精神疾病杂志,1987(03).
  • 4李庆扬等.数值分析[M]华中理工大学出版社,1986.

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部