通过理论分析和试验研究,对设置砼构造柱砖砌体结构的受压承载力建立了两种计算方法,为采用240mm厚砖墙建造中高层混合结构房屋提供了依据.
Based on the theoretical analgsis and experimental research, two calculation methods on the com-pressive bearing capacity for brick masonry structure with concrete constructional column is derived. This paper put forward verifications for the structural design of mid-high story brick masonry building by using 240mm thickness of masonry walls.