期刊文献+

高架桥和立交桥的噪声污染与防治 被引量:19

Study on Traffic Noise and Countermeasures of Viaducts and Overpasses
下载PDF
导出
摘要 通过对座落于深圳市罗湖区的4条主要高架桥、立交桥周围声环境的24h连续监测发现:高架桥的噪声变化趋势与一般干道类似,其最大值出现在离桥面10~15 m的楼层,而立交桥的纵向噪声总体变化不大;对于临路第1排建筑物的高层部分(10楼以上),由于其纳声范围较广,相对而言,桥上的交通噪声对其贡献较小.因此,高架桥、立交桥噪声污染防治应以规划为主,并根据实际情况,采取设置声屏障和隔声窗相结合进行防护. Through 24-hour continuous monitoring of the traffic noise of 4 viaducts and overpasses in Luohu District, Shenzhen City, it is found that the Leq value of the viaducts changes like the normal main roads, and the maximum value appears at 10 ~15 m over the surface of the viaducts; the Leq value of overpasses does not change a lot. For the high part (over 10 floors) of the fist-line buildings besides the roads, the noise contribution from viaduct or overpass traffic is not major. The noise prevention and control must be based on actual circumstances, and jointly apply noise barriers and windows for sound insulation. Above all, a good planning is very important.
出处 《环境科学研究》 EI CAS CSCD 北大核心 2005年第6期120-125,共6页 Research of Environmental Sciences
关键词 高架桥 立交桥 噪声污染 防治 viaduct overpass noise pollution countermeasure
  • 相关文献

参考文献3

  • 1盛晔,潘仲麟.高架复合道路噪声声场分布研究[J].环境污染与防治,2002,24(6):368-369. 被引量:12
  • 2中国科学院声学所,国家环境保护总局.城市道路交通噪声控制研究[R].北京:中国科学院声学所,1988.
  • 3党川.深圳市道路交通声屏障可行性研究总报告[R].深圳:深圳市环保局,1995.22.