摘要
根据JGJ 102-2003和GB 50017-2003两种规范,介绍了玻璃幕墙的螺栓、焊缝、钢角码的计算方法,并列举了实例,指出幕墙设计人员应重视连接的设计计算工作,确保幕墙结构的安全性、可靠性。
According to codes of JGJ 102-2003 and GB 50017-2003 the calculation methods of bolt, weld joint and steel angle bracket of glass curtain wall are introduced. Combined with practice author points out designers should pay more attention on design calculation to ensure the safety and reliability of curtain wall structure.
出处
《山西建筑》
2006年第1期95-96,共2页
Shanxi Architecture
关键词
玻璃幕墙
连接计算
焊缝
glass oartain wall, connection calculation, weld joint