摘要 Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference circuit was also introduced in the middle voltage link of inverter to avoid the shift of the optimum PF point caused by the change of the load and the reliable run of the control system was assured. The experi-ment results show that it has a good self-adaptation in the whole scope of speed ad-justment and an obvious economization on energy while it runs under load. Deduced the relationship between the power factor (PF) and the angular frequency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference circuit was also introduced in the middle voltage link of inverter to avoid the shift of the optimum PF point caused by the change of the load and the reliable run of the control system was assured. The experiment results show that it has a good self-adaptation in the whole scope of speed adjustment and an obvious economization on energy while it runs under load.
机构地区 Electrical Department
出处 《Journal of Coal Science & Engineering(China)》 2005年第2期86-89,共4页 煤炭学报(英文版)
基金 Supported by Liaoning Educational Foundation(202183386)
关键词 异步电机 节能 功率因数 频率控制系统 自动控制 asynchronous motor power factor(PF) auto-control economization on energy