水解—好氧处理制药废水的试验研究 被引量:16

Experimental Study on Treatment of Pharmaceutical Wastewater by Hydrolysis Aerobic Process
下载PDF
导出
摘要 采用水解与好氧相结合技术处理制药废水,在加入生活污水后制药废水易于处理。试验结果表明,进水CODCr和BOD5的浓度为2800mg/L和1040mg/L,经过水解酸化和两级接触氧化处理后,出水COD和BOD浓度分别为98.6mg/L和28.5mg/L,COD和BOD的总去除率分别为96.5%和97.3%,能满足国家污水综合排放标准的要求。 The technology combined hydrolysis with aerobic process was used to treat pharmaceutical wastewater, which was easy to be treated when mixing with domestic wastewater. Experimental results showed that the effluent concentration of CODcr and BOD5 were 98.6mg/L and 28.5mg/L, removal rate of CODcr and BOD5 were 96.5% and 97.3% respectively when influent CODcr and BOD5 of 2800mg/L and 1040mg/L was treated by hydrolysis and two stage aerobic process, which can meet the discharge standard.
出处 《环境科学与技术》 CAS CSCD 北大核心 2006年第1期82-83,共2页 Environmental Science & Technology
关键词 化学制药废水 生活污水 水解 接触氧化 pharmaceutical wastewater domestic wastewater hydrolysis contact oxidation
  • 相关文献

参考文献3

  • 1陆杰,徐高田,张玲,张国莹.制药工业废水处理技术[J].工业水处理,2001,21(10):1-4. 被引量:59
  • 2H V Hendiriksen, B K Ahring. Anaerobic Dechlorination of Pentachlorophenol in Fixed-film and Upflow Anaerobic Sludge Blanket Reactors Using Different Inocula [J].Biodegradation, 1992,(3): 339.
  • 3J W Grave, T W Joyce. A Critical Review of the Ability of Biological Treatment Systems to Remove Chlorinated Organics Discharged by the Paper Industry [J]. Water SA ,1994,20:155-160.

二级参考文献60