摘要 分析了原动机在民用建筑物内设置、运行可能产生的危险因素,根据这些危险因素分析阐述了机房设置的安全技术原则是预防为主,通过提供安全可靠的技术设备、多种检测手段及良好的通风环境,使发生事故的可能性降至最低。同时加强建筑物的安全措施做好准备,万一发生事故,能使事故产生的损失减小到最低限度。 The article analyzes the unsafe factors of the prime movers which are located or operated in civil building. According to these factors, we analyze and set forth that prevention is the main safety technology principle guiding the layout and location of the station. The possibility of the accident can be minimized by means of providing safe and reliable technology and equipments, many kinds of inspection measures as well as sound ventilation environment. Meanwhile we are ready to strengthen the building safety measures in order to minimize the loss in case of the accident.
出处 《上海节能》 2005年第6期66-76,共11页 Shanghai Energy Saving
关键词 天然气 原动机 安全技术措施 良好的通风环境 防爆墙 站房的泄爆面积 natural gas, prime mover, safety technology measures, sound ventilation environment, explosion protection wall, explosion discharge areas of the station
  • 相关文献

参考文献2

  • 1GB 50019-2003.采暖通风与空气调节设计规范[S],2003.
  • 2GB 50058-1992.爆炸和火灾危险环境电力装置设计规范[S],1992.