以黄龙滩电厂1号机组稳定性试验为例,介绍了黄龙滩电厂扩建工程1号机组在启动试运行过程中,进行机组稳定性试验、监测与评价;根据试验分析结果,黄龙滩电厂扩建工程1号机组应避免在50%额定负荷以下运行。
Taking the stability test of No 1 generating set of expansion project of Huanglongtan Pow- er plant for example,the stability test,the monitoring and evaluation of generating set during the commissioning were introduced. According to the analysis of the test results,it was concluded that No 1 generating set of expansion project should avoid operating at output lower than 50% rated power.