采用微波消化测定动物组织中微量的铝。先用硝酸高压溶解,然后用石墨炉原子吸收测定。方法的检出限0.91 ng/ml,线性范围0-1000 ng/ml,其回收率为95.1%-104.7%.该方法简化了对动物组织中铝测定的消化,精密度高,检出限低。
Determination of aluminium in viscera is conducted by adopting microwave digestion technique. It is determined with nitric acid in a high - pressure microwave oven and then analyzed by graphite furnace atomic absorption spectrometry. The detection limit is 0.91ng/ml, The calibration lines are linear in the range of 0 -- 1000 ng/ml, and the recoveries of these materials range from 95.1% to 104.8 %. The method is simple, accurate and low on the detection limit.
出处
《贵州工业大学学报(自然科学版)》
CAS
2005年第6期100-102,共3页
Journal of Guizhou University of Technology(Natural Science Edition)
关键词
微波消化
动物组织
石墨炉原子吸收
铝
microwave digestion
viscera
graphite furnace atomic absorption spectrometry
aluminium