期刊文献+

磁共振成像设备新进展 被引量:9

The new development of magnetic resonance imaging
下载PDF
导出
摘要 受益于高科技特别是计算机技术的飞速发展,磁共振成像设备近年来呈现出飞速发展的态势,体现为超高场、短磁体、开放性以及低损耗等方面的高性能磁体、高性能的双梯度系统以及减低涡流、静音降噪技术,多通道相控阵线圈以及并行采集技术等,提高了图像信噪比,缩短了扫描时间,为许多新技术在临床的运用奠定了硬件的基础,很好地解决了困扰临床很长时间的伪影、心血管成像等难题,满足临床与科研的需要。高性能的计算机系统、后处理工作站、DICOM3.0兼容、以及人性化的操作界面是磁共振另一特点。 The development of MR focuses in high performance magnet, twin grads technology, phased array coil and parallel imaging technology. These technologies raise SNR of images and shorten the imaging time. Many new clinical technologies have been opened out in order to solve the problems which have been faced for a long time, such as artifacts, imaging of heart and so on. They also meet the needs of clinic and scientific research. Other advancements in MRI technology have made in high performance computer, advance data management and so on.
作者 倪萍 蔡华
出处 《医疗设备信息》 2005年第12期1-4,共4页 Information of Medical Equipment
关键词 磁体性能 梯度 并行采集 磁共振成像 设备 MRI magnet performance twin grads parallel imaging
  • 相关文献

参考文献6

  • 1徐子森,苗元青,王燕.3.0TMR的进展现状及优势分析[J].医疗设备信息,2005,20(2):38-39. 被引量:4
  • 2王秀彬,胡振民.磁共振成像相阵控线圈及并行成像技术[J].医疗卫生装备,2005,26(6):19-20. 被引量:18
  • 3Pruessman KP, Weiger M, et al. SENSE: Sensitivity encoding for fast MRI[J]. Magn Reson Med,1999,42(4):952-962.
  • 4Medina LS, Aguirre E, Bernal B, Ahman NR. Functional imaging versus Wada test for the evaluation of language lateralization: cost analysis[J]. Radiology ,2004,230:49 - 54.
  • 5Ibrahim T, Nekolla SG, Schreiber K, et al. Assessment of coronary flow reserve: comparison between contrast- enhanced magnetic resonance imaging and positron emission tomography[J]. J Am Coll Cardiol, 2002,39:864 - 870.
  • 6Sodickson DK, McKenzie CA. A generalized approach to parallel magnetic resonance imaging[J]. Med Phys,2001,28:1629-1643.

二级参考文献19

  • 1Pruessmann KP,Weiger M,Scheidegger MB,et al. SENSE:Sensitivity encoding for fast MRI. Magn Reson Med, 1999,42(4):952~962.
  • 2Roemer PB,Edelstein WA,Hayes CE, et al. The NMR phasedarray. Magn Reson Med,1999,16(1):192~225.
  • 3Hutchinson M,Raff U. Fast MRI data acqusition using multiple detectors. Magn Reson Med, 1988,6(1):87~91.
  • 4Hayes CE,Hattes N,Roemer PB. Volume imaging with MR phaded arrays. Magn Reson Med, 1991,18(2):309~319.
  • 5Kwiat D,Einav S,Navon G. A decoupled coil detector array for fast image acquisition in magnetic resonance imaging. Med phys1991,18:251~265.
  • 6J.R. Kelton,R.L. Magin, S.M.Wright. An algorithm for rapid image acquisition using multiple receive coil ,Eighth annual Meeting,SMRM,Amsterdam,Netherlands, 1989.1172.
  • 7Ra JB,Rim CY. Fast imaging using sub-encoding data sets from multiple detectors. Magn Reson Med. 1993,30(1):142~145.
  • 8Carlson JW,Minemura T.Imaging (time reduction through multiple receiver coil data acquisition and imagie reconstruction. Magn Reson Med, 1993,29(4):681~688.
  • 9Sodickson DK,Manning WJ. Simultaneous acqusition of spatial hamonics (SMASH):Fast imaging with radiofrequency coilarraysd Magn Reson Med,1997,38(3):591~603.
  • 10Peterson D.M.,DuensingG.R.,Fizsimmons J.R. MRI basics and coil design principles. RF Design, 1997 ( 1 ): 56.

共引文献20

同被引文献50

引证文献9

二级引证文献60

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部