期刊文献+

SPR生物传感系统及其对DNA的检测分析 被引量:6

SPR Biosensor-Based System and its Use in the Detection Analysis of DNA
下载PDF
导出
摘要 智能化的SPR生物传感系统采用独特的角向会聚光路代替传统的角度机械扫描方式,采用CCD作为光电检测器件,避免了机械扫描可能带来的误差,可一次完成样品响应曲线的采集分析,提高了检测精度和速度。此外,利用MATLAB软件对信号进行了FIR滤波分析处理,提高了信噪比。利用所研制的系统,分别对DNA分子的体响应以及DNA分子杂交过程进行了检测分析,并且得到了较为满意的结果。 A set of intelligentized SPR biosensor-based system was developed. A unique angle converging optical configuration was used in the system instead of the traditional way of mechanical angular scan while a CCD camera forms the photoelectric detector. This method is of benefit to increase examination accuracy and speed because it can reduce the error brought by the use of moving parts and can obtain the response curve for a sample in a lump. Furthermore, the signal was processed by the FIR filter to enhance the signal-to-noise ratio using the MATLAB software. Using this system, the bulk response and intercross
出处 《传感技术学报》 CAS CSCD 北大核心 2005年第4期700-704,共5页 Chinese Journal of Sensors and Actuators
基金 天津市自然科学基金(023602711) 国家自然科学基金(60574091) 南开大学科技创新基金
关键词 表面等离子共振 生物传感器DNA surface plasmon resonance biosensor DNA
  • 相关文献

参考文献8

  • 1刘国华,文可,牛文成.表面激元共振(SPR)传感器理论分析[J].仪表技术与传感器,2003(11):1-3. 被引量:10
  • 2B.Liedberg,C.Nylander,I.Lundstr m,Surface plasmons resonance for gas detection and biosensing[J].Sensors and Actuators 1983,4:299-304.
  • 3N.L.Dmitruk,O.I.Mayeva,S.V.Mamykin,O.B.Yastrubchak,M.Klopfleisch,Characterization and application of multilayer diffraction gratings as optochemical sensors[J].Sensors and Actuators A:2001,Physical Volume 88,Issue 1:52-57.
  • 4Toyama.Shigeru,Doumae.Narumasa,Shoji.Atsumu,Ikariyama.Yoshihito,Design and fabrication of a waveguide-coupled prism device for surface plasmon resonance sensor[J].Sensors and Actuators B:2000,Chemical Volume 65,Issue:1-3:32-34.
  • 5Piliarik,M.;Homola,J.;Maníková,Z.;Ctyrok J.Surface plasmon resonance sensor based on a single-mode polarization-maintaining optical fiber[J].Sensors and Actuators B:April 20,2003,Chemical Volume 90,Issue 1-3:236-242.
  • 6A.Otto.Excitation of nonradiative surface plasma waves in silver by the method of frustrated total reflection[J].Z.Physik,1968,216:398-410.
  • 7E.Kretschmann,H.Raether.Radiative decay of non-radiative surface plasmons excited by light[J].Z.Naturforsch,1968,23A:2135-2136.
  • 8H.Morgan,D.M.Taylor,A surface plasmon resonance immunosensor based on the streptavidin biotin complex[J].Biosensors Bioelectron.1998,7:405-410.

二级参考文献8

  • 1ALFTILAN K J.Surface plasmon resonance biosensors as a tool in antibody engineering Biosensors & Bioelectronics,1998(13):653—663.
  • 2NENNINGER G G, TOBISKA P, HOMOkA J, et al. Long-range surface plasmons for high-resolution surface plasmon resonance sensors. Sensors and Actuators B, 2001 (74) : 145 - 151.
  • 3HOMOLA J, LU H B, NENNINGER G G, et al. A novel multichannel surface plasmon resonance biosensor. Sensors and Actuators B. 2001 (76) :403 - 410.
  • 4SALAMON Z, WANG Y,TOLLIN G, et al. Assembly and molecular organization of self-assembled hpid bilayers on solid substrates monitored by surface plasmon resonance spectroscopy. Biochimica et Biophysica Acta,1994(1195):267 -275.
  • 5K.RE3SCHMANN E, RAETHER H. Radiative Decay of Nonradiative Surface Plasmons Excited by Light, Z. Naturforsch. 23a, 1968:2135 - 2136.
  • 6OTTO A. Excitation of Nonradiative Surface Plasma Waves in Silver by the Method of Frustrated Total Reflection. Zeitschrift fuer Physik, 1968 (216) :398 - 410.
  • 7SALAMON Z, ANGUS M H, TOLLIN G. Surface plasmon resonace spectroscopy as a tool for investionating the biochemical and biophysical properties of membrance protein systems. Biochimica et Biophysica Acta, 1997(1331) :117- 129.
  • 8HOMOLA J,YEE S Y,GAUGLIIZ G Surface plasmon resonance sensors:renew Sensors and Actuators B,1999(54):3—15.

共引文献9

同被引文献66

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史