摘要 目的评价旋转DSA对脑动脉瘤的诊断价值。方法回顾性总结37例脑动脉瘤的旋转DSA影像表现,分析脑动脉瘤的位置、大小、形态、数目及检查方法。结果检出脑动脉瘤单发34例,多发3例。37例中查出脑动脉瘤39个,其中,后交通动脉瘤20个,前交通动脉瘤13个,颈内动脉瘤2个,其他部位4个;小型7个,中型18个,大型13个,巨型1个;囊状28个,梭状11个。结论旋转DSA能准确诊断脑动脉瘤。 Objective To evaluate the diagnostic value of rotary digital subtraction angiography (R-DSA)for intracranial aneurysms. Methods DSA imaging data of 37 patients with clinically suspected intracranial aneuryam, which included the location, size, shape and number of the lesions of aneurysm and the examination method were retrospectively summarized and analyzed. Results Among 37cases, 34 cases(91% )were single aneurysms and 3 cases (9 % )were multiple aneurysms. Among 39 aneurysms of 37 cases, 20 located in posterior communicating arteries, 13 in anterior communicating arteries, 2 in internal carotid arteries and 4 in other locations. For the size of the aneurysm(in diameter), there were 7 small ( 〈0.5 cm),18 middle ( 0.5-1.0cm ), 13 large (1.1 -2.5cm),and 1 giant (〉 2.5 cm) in 39 aneurysms. For the shape of the aneurysms, 28 were cystiform and 11 were fusiform. Conclusion R-DSA can accurately diagnose intracranial aneurysm.
出处 《实用医学影像杂志》 2005年第4期190-191,共2页 Journal of Practical Medical Imaging
关键词 旋转DSA 脑动脉瘤 脑血管造影 R-DSA Aneurysm, intracranial Angiography, cerebral
  • 相关文献

参考文献4

二级参考文献10

  • 1Tu RK,Cohen WA,Maravilla KR,et al.Digital subtraction rotational angiography for aneurysms of intracranial anterior circulation:injection method and optimization[J].AJNR,1996,17(6):1127-1136.
  • 2Tu RK, Cohen WA, Maravilla KR, et al. Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: injection method and optimization. AJNR Am J Neuroradiol, 1996, 17(6):1127-1136.
  • 3Fahrig R, Fox AJ, Lownie S, et al. Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR Am J Neuroradiol, 1997, 18(8): 1507-1514.
  • 4Heautot JF, Chabert E, Gandon Y, et al. Analysis of cerelrvascular diseases by a new 3-dimensional computerised X-ray angiography systen.Ne uroradiology, 1998, 40(4): 203-209.
  • 5Anxionnat R, Bracard S, Macho J, et al. 3D angiography. Clinical interest. First applications in interventional neuroradiology. J Neuroradiol,1998, 25(4): 251-262.
  • 6Tantivatana J, Kim SJ, Chavali RV, et al. 3D angiography in evaluation of intracranial aneurysmm and arteriovenous malformation ( abstract). Intervent Neuroradiol, 1999,5( suppl 1 ) :80.
  • 7Schumacher M, Husstedt H. Accuracy of 3D angiography and 3D CTA in measurement of vessel diameter (abstract). Intervent Neuroradiol, 1999,5 (suppl 1 ): 87.
  • 8Moret J, Weill A, Piotin M, et al. Why 3D angiography has become mandatory for treatment of intracranial berry aneurysm? analysis and results over 100 aneurysms( abstract ). Intervent Neuroradiol, 1999,5 ( suppl1):64.
  • 9Bendib K, Poirier C, Croisille P, et al. Characterization of arterial stenosis using 3D imaging. Comparison of 3 imaging techniques (MRI, spiral CT and 3D DSA) and 4 display methods (MIP, SR, MPVR, VA) by using physical phantoms. J Radiol, 1999, 80(11): 1561-1567.
  • 10赵军,杨进全,吴宁,邢丽.旋转DSA应用于头颈部的技术探讨[J].中华放射学杂志,2000,34(1):29-30. 被引量:29

共引文献45

同被引文献3

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部