期刊文献+

曝气-过滤一体化装置处理城市污水效果的研究 被引量:1

STUDY ON URBAN WASTEWATER TREATMENT BY INTEGRATED OXIDATION-FILTRATION REACTOR
下载PDF
导出
摘要 曝气-过滤一体化装置主要由生物反应器、慢性砂滤池及滤布组成。装置对城市污水的处理效果比较好,正常情况下,对COD和NH3-H去除率达90%以上,出水SS为零,出水浊度不超过6 NTU,但对总氮和总磷的去除率分别低于20%和16%,出水细菌总数超过6×104MPN/mL。 Integrated Oxidation- Filtration Reactor which consists reasonably of a bioreactor, a slow filter and a piece of filter fabric, can efficiently treat urban wastewater. Normally the removal efficiency of COD and NH3- N by this process is mole than 90%, but that of TN and TP is less than 20% and 16% respectively. In its treated water, the SS is zero, the nephelo is less than 6NUT, and the total number of bacteria is more than 6 × 10^4MPN/mL.
出处 《能源环境保护》 2005年第6期30-33,共4页 Energy Environmental Protection
关键词 曝气-过滤一体化装置 COD SS 浊度 氨氮 Integrated Oxidation - Filtration Reactor, COD, SS, NH3 - N
  • 相关文献

参考文献5

二级参考文献12

  • 1罗虹 顾平 等.应用序批式膜生物反应器处理生活污水的研究.全国污水处理除磷脱氮技术研讨会论文集[M].上海,2000..
  • 2国家环保局.水和水质监测分析方法3[M].北京:中国环境科学出版社,1987..
  • 3罗虹,全国污水处理除磷脱氮技术研讨会论文集,2000年
  • 4Clark J G. Select the Right Fabric Media for Liquid-SolidSeparation. Chemical Engineering Progress, 1990, 86 ( 11 ):45 ~ 50
  • 5RushtonA,GriffithsPVR.RoleofClothinFiltration.Fil&Sep,1972,9(1):81-89
  • 6克莱德@奥尔.过滤理论与实践.北京:国防工业出版社,1982
  • 7斯瓦洛夫斯基等.固液分离.北京:原子能出版社,1982
  • 8张志勇,姚公弼.进料浓度与颗粒大小对过滤速率的影响.第一届全国非均相分离学术交流会论文集.1987
  • 9邢传宏,钱易,TardieuEric.超滤膜-生物反应器处理生活污水及其水力学研究[J].环境科学,1997,18(5):19-22. 被引量:30
  • 10杨造燕,匡志花,顾平,田淑媛.膜生物反应器无剩余污泥排放的研究[J].城市环境与城市生态,1999,12(1):16-18. 被引量:48

共引文献133

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部