摘要
免维护电池和阀控电池对充电电压很敏感,而添加负极膨胀剂又强烈影响电池的充电接受性能。论述了免维护电池和阀控密封电池对充电电压的要求,试验确定了采用不同负极有机膨胀剂、适用于汽车起动用富液免维护电池的适宜的充电电压。
Maintenance-free battery and valve-regulated storage battery are very sensitive to the charging voltage. At the same time, the charge acceptance capability will be influenced evidently by the negative expander adopted. The requirements of the maintenance-free battery and valve-regulated battery for charging voltage are discussed in this article, A suitable voltage relative to different organic negative expander mixture has been confirmed through experiments for flooded maintenance-free battery used as SLI type.
出处
《蓄电池》
北大核心
2005年第4期150-152,共3页
Chinese LABAT Man
关键词
铅酸蓄电池
充电电压
lead-acid battery
charging voltage