期刊文献+

原型观测在十三陵蓄能电厂2#水道系统安全检查中的应用 被引量:2

Application of Antitype Observation in Safety Inspection of 2# Channel System of Shisanling Storage Plant
下载PDF
导出
摘要 通过对压力钢管运行期原型观测及分析,掌握了2#水道系统压力钢管关键部位的安全状况,为2#水道系统首次检查提供了严谨的决策依据。2#水道系统放充水期间的实时监测成果,不仅真实地反映了压力钢管的受力变化情况,而且检验了原型观测设施和仪器的可靠度,通过实践证明多数仪器都能灵敏的反映压力管道的实际运行情况。 Through observation and analysis on antitype of steel pressure pipe in operation phase, safety situation of key parts of steel pressure pipes in 2# Channel system can be controlled to provide basis for decision making in initial inspection of the system. Real-time monitoring results for the phase of water discharge and filling not only indicated changing cause of the pipe under pressure, and checked the reliability of equipment and instruments for antitype observation. Through practice, most of instruments are proved to be able to reflect actual situation.
出处 《水利水文自动化》 2005年第4期28-31,共4页 Automation in Water Resources and Hydrology
关键词 水道系统 原型观测 安全检查 允许应力 实测应力 water channel system antitype observation safety inspection stress allowed real stress
  • 相关文献

参考文献2

  • 1关于批准发布《水电站压力钢管设计规范》SL281-2003的通知[J]水利技术监督,2003(04).
  • 2SL 281-2003.水电站压力钢管设计规范[S],2003.

同被引文献11

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部