摘要 近年来随着集散控制系统(distributedcontrolsystem;DCS)在电力生产过程中的普遍运用,发电过程自动化水平虽有所提升,但部分机组运行的安全、稳定性并未明显提高。由于电源系统自身原因而导致的控制系统失灵,影响机组的稳定运行也时有发生。该文介绍了江西省火力发电厂热工电源的设计现状,分析了其设计原理、存在不足,并提出了改进措施。 In recent years, along with the distributed control system in the electric power production line of widespread application,the automation level of generation process although have to promote, the safety, stability for circulating of part of machines didn't obviously increase.Because of the control system that power supply system itself reason and cause out of order, influence the stability of the machine set.This text introduced the JiangXi thermal power plant the design present condition of the thermal control system power supply, and analyze the principle of its design, exit lack, and propose the improvement measure.
作者 卢铭庆
出处 《江西电力》 2005年第6期27-29,共3页 Jiangxi Electric Power
关键词 集散控制系统 电源设计 可靠性分析 control 火力发电厂 system 电力生产过程 机组运行 自动化水平 电源系统 thermal power plant thermodynamic power supply system design flaw improvement