从各个方面分析了凝结水过冷度产生的原因及其对机组运行经济性、安全性的影响,从凝汽器的设计、改造、检修以及运行维护的角度,提出了减小凝结水过冷度的对策,以此来提高机组运行的经济性和安全性。
Some reasons of condensate subcooling occurrence and its effects on safe & economic performance of power unit have been analyzed in many respects facets in this article. And the writers put forward some countermeasures about decreasing condensate subcooled degree in terms of design, renovation, operation and maintenance in order to improve the safe & economic performance of power unit.
出处
《电站辅机》
2005年第4期22-26,共5页
Power Station Auxiliary Equipment
关键词
凝汽器
过冷度
经济性
安全性
condenser
subcooled degree
eeonomy
safety